![]() ![]() ![]() We report and discuss the test measurement results on a full-scale copper prototype, showing good agreement with CST RF simulations. (3) Results: This device is a nine-cell structure operating on the π / 2 mode at 5.712 GHz (C-band). The measurements of the field in the cavity have been done with the bead-pull technique. (2) Methods: We performed the RF electromagnetic design of the prototype of the C band linac using CST STUDIO Suite Code and the RF low power RF test at Sapienza University of Rome. In this contest, Sapienza University, in collaboration with SIT-Sordina IORT Technology spa, is developing a new C-band linac to achieve the FLASH regime. In order to obtain a high dose in a very short time, accelerators with high-intensity currents (the order of 100 mA peak currents) have to be developed. It releases ultra-high radiation dose rates (above 100 Gy/s) in microsecond short pulses. (1) Background: FLASH Radiotherapy (RT) is a revolutionary new technique for cancer cure. In this paper, we illustrate the RF design and measurements of a C-band prototype structure for an Ultra High Dose Rate medical linac. ![]()